OT FIT 30/220 240/125 D L
- Small housing design
- Fixed current
- Lifetime: up to 100,000 h (temperature at Tc = 65 °C, max. 10 % failure rate)
- High quality of light thanks to low output ripple current
- High efficiency
- Fulfill safety requirement due to overload, overtemperature, Hot Plug protection
- Linear lighting for office, education, industry, storage areas and retail
- Installation in emergency lighting systems according to IEC 61347-2-13, appendix J
- Suitable for installation in emergency lighting systems according to EN 60598-2-22
- Suitable for luminaires of protection class I
Technical Data
Electrical data
Nominal input voltage
220 240 V
Mains frequency
0/50/60 Hz
Input voltage AC
198 264 V
Current set
Fixed current
Input voltage DC
176 276 V
Total harmonic distortion
< 20 %
Power factor λ
> 0.95
Efficiency in full-load
90 %
Device power loss
3.0 W
Protective conductor current
<2.0 mA
Max. ECG no. on circuit breaker 10 A (B)
35
Max. ECG no. on circuit breaker 16 A (B)
56
Max. ECG no. on circuit breaker 25 A (B)
-
Surge capability (L/N-Ground)
2 kV
Surge capability (L-N)
1 kV
Nominal output voltage
54 216 V
U-OUT (working voltage)
< 250 V
Nominal output current
125 mA
Output current tolerance
±10 %
Output ripple current (100 Hz)
< 10 %
Output PSTLM
≤1
Output SVM
≤0.4
Nominal output power
6.8 27 W
Maximum output power
27 W
Galvanic isolation
Non isolated
Default output current
125 mA
Galvanic isolation primary/secondary
-
Dimensions & weight
Mounting hole spacing, length
200.0 mm
Product weight
125.00 g
Cable cross-section, input side
0.5 1.5 mm²
Cable cross-section, output side
0.5 1.5 mm²
Wire preparation length, input side
8.5 9.5 mm
Wire preparation length, output side
8.5 9.5 mm
Width
30.0 mm
Height
21.0 mm
Length
210.0 mm
Colors & materials
Casing material
Metal
Temperatures & operating conditions
Ambient temperature range
-15 +50 °C
Maximum temperature at tc test point
75 °C
Max.housing temperature in case of fault
110 °C
Temperature range at storage
-25 85 °C
Permitted rel. humidity during operation
5 85 %
Lifespan
ECG lifetime
50000 / 100000 h
Capabilities
Dimmable
No
Overheating protection
Automatic reversible
Overload protection
Automatic reversible
Short-circuit protection
Automatic reversible
No-load proof
Yes
Intended for no-load operation
No
Max. cable length to lamp/LED module
2.0 m
Suitable for fixtures with prot. class
I
Suitable for emergency lighting
Yes
Type of connection, input side
Push terminal
Type of connection, output side
Push terminal
Number of channels
1
Certificates & standards
Approval marks approval
CE / EL / VDE-ENEC / VDE-EMC / EAC / CCC / BIS / RCM
Standards
Acc. to EN 61347-1/Acc. to EN 61347-2-13/Acc. to EN 55015/Acc. to EN 61547/Acc. to EN 61000-3-2/Acc. to EN 62384/Acc. to EN 62386
Protection class
I
Type of protection
IP20
Logistical data
Commodity code
85044083900
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
21-07-2023
Primary Article Identifier
4052899222557
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
a4060b4e-4228-49cd-9dec-83aeb3e6b2c3
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4052899222557 |
UNV
| 1 | 210mm x 30mm x 21mm | 125.00g | 0.13dm³ |
4052899222564 |
VS
| 20 | 234mm x 161mm x 101mm | 2665.00g | 3.81dm³ |
Downloads
Data sheets
Information about Family
Remarkable about this product is the small housing which is only 210mm long and the high efficiency of up to 90%. A dedicated current per driver and a low ripple contributing to the lighting quality mark some additional characteristics. This device is also suitable for emergency lighting units.
- Line frequency: 0 Hz | 50 Hz | 60 Hz
- Versatile scope of application due to output power range of up to 50 W
- Supply voltage: 220 240 V
- Available with output current range: up to 350 mA
- Non-isolated drivers
Intended for use with LED modules.
The forward voltage of the LED light source shall be within the defined operating window of the control gear in all operating conditions including dimming if applicable.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|---|
![]() |
OT FIT 30/220
240/125 D L
|
54 216 V | 125 mA | 210.0 mm | 30.0 mm | 21.0 mm | ||
![]() |
OT FIT 45/220
240/200 D L
|
54 216 V | 200 mA | 210.0 mm | 30.0 mm | 21.0 mm | ||
![]() |
OT FIT 50/220
240/250 D L
|
54 216 V | 250 mA | 210.0 mm | 30.0 mm | 21.0 mm | ||
![]() |
OT FIT 50/220
240/300 D L
|
54 175 V | 300 mA | 210.0 mm | 30.0 mm | 21.0 mm | ||
![]() |
OT FIT 50/220
240/350 D L
|
54 150 V | 350 mA | 210.0 mm | 30.0 mm | 21.0 mm |