OT 75/220...240/1A0 1DIM G2 CE
- Easy and fast wireless luminaire programming
- Very high efficiency
- Optimized for AstroDIM operation
- Wide current output range: 200 mA 1050 mA
- High surge protection: up to 10 kV (in protection class I or II)
- Great flexibility due to wide operating temperature range of -40 55 °C
- Protection through double isolation between mains input and LED output
- Street and urban lighting
- Industry
- Suitable for outdoor applications in luminaires with IP > 65
- Suitable for use in outdoor luminaires of protection class I and II
Technical Data
Electrical data
Nominal voltage
220 240 V
Input voltage AC
198 264 V
Nominal current
0.36 A
Mains frequency
50 60 Hz
Power factor λ
0.58C 0.99
Total harmonic distortion
< 5 %
Device power loss
6.0 W
Inrush current
52 A
Max. ECG no. on circuit breaker 10 A (B)
8
Max. ECG no. on circuit breaker 16 A (B)
13
Max. ECG no. on circuit breaker 25 A (B)
20
Surge capability (L/N-Ground)
10 kV
Surge capability (L-N)
6 kV
Nominal output power
75 W
Maximum output power
75 W
Efficiency in full-load
92 %
Nominal output current
200 1050 mA
Output current tolerance
±3 %
Output ripple current (100 Hz)
< 5 %
Output PSTLM
≤1
Output SVM
≤0.4
Minimum output current
70 mA
Galvanic isolation
Double
U-OUT (working voltage)
150 V
Nominal output voltage
35 115 V
Max. ECG no. on circuit breaker 16 A (C)
22
Max. no. of ECGs on 16A MCB with EBN-OS
30
Max. ECG no. on circuit breaker 10 A (C)
14
Dimensions & weight
Length
133.0 mm
Width
77.0 mm
Height
40.0 mm
Mounting hole spacing, length
122.5 mm
Mounting hole spacing, width
-
Product weight
260.00 g
Cable cross-section, input side
0.2 1.5 mm²
Cable cross-section, output side
0.2 1.5 mm²
Wire preparation length, input side
8.5 9.5 mm
Temperatures & operating conditions
Ambient temperature range
-40 +55 °C
Temperature range at storage
-25 85 °C
Maximum temperature at tc test point
85 °C
Max.housing temperature in case of fault
120 °C
Permitted rel. humidity during operation
5 85 %
Lifespan
ECG lifetime
50000 / 100000 h
Capabilities
Dimmable
Yes
Dimming interface
AstroDIM
Dimming range
10 100 %
Suitable for fixtures with prot. class
I / II
Constant lumen function
Programmable
Short-circuit protection
Automatic reversible
No-load proof
Yes
Intended for no-load operation
No
Max. cable length to lamp/LED module
2.0 m
Overload protection
Automatic reversible
Number of channels
1
Programming
Programming device
NFC
Certificates & standards
Type of protection
IP20
Standards
Acc. to EN 61347-1:2015/Acc. to EN 61347-2-13:2014 + A1:2017/Acc. to EN 62384:2006 + A1:2009-09/Acc. to EN 55015:2013 + A1:2015/Acc. to EN 61000-3-2:2014/Acc. to EN 61000-3-3:2013/Acc. to EN 61547:2009/Acc. to ETSI EN 301 489-3 V2.1.1 (2019-03)
Approval marks approval
CE / ENEC / VDE / VDE-EMC / CCC / EAC
Logistical data
Commodity code
85044083900
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
05-10-2023
Primary Article Identifier
4052899605367
Candidate List Substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe Use Instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Declaration No. in SCIP database
0d4d02cb-ba62-49da-a198-f21a4f16826b
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4052899605367 |
UNV
| 1 | 133mm x 77mm x 40mm | 260.00g | 0.41dm³ |
4062172279192 |
VS
| 10 | 300mm x 210mm x 100mm | 2823.00g | 6.30dm³ |
Downloads
Data sheets
Accessories optional
Information about Family
An easy and fast wireless luminaire programming is made possible via NFC. The AstroDIM operation for which this driver is optimized allows autonomous dimming with five independent levels (astro, time mode). The surge protection goes up to 10 kV which correspond to protection class I or II.
- Supply voltage: 220 240 V
- Current output range: 70 1,050 mA
- AstroDIM for autonomous dimming with five independent levels (astro, time mode)
- Standby power consumption: < 0.5 W
- Constant Lumen Output (CLO)
- Integrated customizable thermal management (Driver Guard)
Intended for use with LED modules.
The forward voltage of the LED light source shall be within the defined operating window of the control gear in all operating conditions including dimming if applicable.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|
![]() |
OT 20/170
240/1A0 1DIMLT2 G1 CE
|
200 1050 mA | 123.0 mm | 79.0 mm | 33.0 mm | ||
![]() |
OT 40/170
240/1A0 1DIMLT2 G1 CE
|
200 1050 mA | 123.0 mm | 79.0 mm | 33.0 mm | ||
![]() |
OT 75/170
240/1A0 1DIMLT2 G1 CE
|
200 1050 mA | 133.0 mm | 77.0 mm | 40.0 mm | ||
![]() |
OT 110/170...240/1A0 1DIMLT2 G1 CE
|
200 1050 mA | 150.0 mm | 90.0 mm | 40.0 mm | ||
![]() |
OT 75/220...240/1A0 1DIM G2 CE
|
200 1050 mA | 133.0 mm | 77.0 mm | 40.0 mm | ||
![]() |
OT 165/220...240/1A0 1DIM G2 CE
|
200 1050 mA | 150.0 mm | 90.0 mm | 39.5 mm |